Axolotl Tank Cooling Calculator

Compare the wet-bulb limit of fan cooling with your target temperature, estimate tank heat gain, and estimate chiller cooling time. An estimate only, not a safety assessment.

Laboratory Console Engine // SYS.2.5
ONLINE
Calibration Controls
12 Parameters
1-Click Climate Presets Sets Room Temp & RH
10 ยฐC 40 ยฐC
5 % 99 %
10 ยฐC 35 ยฐC
10 ยฐC 25 ยฐC
1 GAL 150 GAL
0 W 100 W
0 ยฐC 10 ยฐC
0.5 hrs 24 hrs
20 W 1000 W
Diagnostic Telemetry
Console Standby

Awaiting Parameter Calibration

Adjust parameters in the left console to initiate real-time telemetry and biological safety verification.

Aquarium Thermodynamics

Standardized Laboratory Specs
Wet-Bulb FormulaStull (2011), RH 5-99%, -20 to 50 C (not valid for low humidity with cold temperature), sea-level pressure
Formula Error-1 to +0.65 C (mean absolute error under 0.3 C)
Heat Capacity of Water4.186 kJ/(kg*K); 1 L = 1 kg
Power to Heat1 W = 3.41214 BTU/h
Heat Gain from WarmingW = L x 4.186 x rise / (3.6 x hours)
Cooling EnergyWh = L x 4.186 x drop / 3.6
Chiller Timehours = Wh / (chiller W - heat gain W)
Volume Conversion1 US gallon = 3.78541 L
โœ“
Target Operational Envelope OPTIMAL

Set by the temperature source you follow; published axolotl ranges differ (10-22 C, 15-18 C, 15.6-17.8 C, 17-18 C)

โš ๏ธ
Critical Operating Boundary HAZARD

If the wet-bulb temperature is at or above the target, evaporation alone cannot reach it. If chiller capacity does not exceed heat gain, a chiller cannot reach it.

Standard Volumetric Calibration Presets Standard Footprints
Room 22 C, 50% RH15.4 C wet-bulb floor
Room 26 C, 50% RH18.9 C wet-bulb floor
Room 28 C, 40% RH18.8 C wet-bulb floor
Room 30 C, 60% RH24.0 C wet-bulb floor
100 L warming 1.5 C in 6 h29.1 W heat gain
100 L cooled 24 to 20 C with 150 W chiller3.8 hours (ignores glass and decor mass)
Failure Mode & Hazard Mitigation Analysis
Treating the Wet-Bulb Floor as a ForecastHIGH

The floor is a lower bound. Verify with a thermometer and plan for a margin.

Heat-Gain Test Started WarmMODERATE

Measure warming starting near the target temperature, because colder water gains heat faster from a warm room.

Unit Mix-Up (W vs BTU/h)MODERATE

Check the chiller rating unit. 1 W = 3.41214 BTU/h.

Using the Result as an Animal-Safety VerdictHIGH

Published ranges differ and the tool does not assess animal health. Consult an exotic-animal veterinarian about a sick animal.

Formula & Calculation Logic

Step 1: convert inputs to C, litres and watts (US gallon = 3.78541 L; BTU/h / 3.41214 = W). Step 2: wet-bulb Tw = T*atan(0.151977*sqrt(RH+8.313659)) + atan(T+RH) - atan(RH-1.676331) + 0.00391838*RH^1.5*atan(0.023101*RH) - 4.686035. If Tw >= target, fan cooling cannot reach the target. Step 3: heat gain (W) = Volume(L) x 4.186 x rise(C) / (3.6 x hours), or equipment watts if no measurement is given. Step 4: energy (Wh) = Volume(L) x 4.186 x (water temp - target) / 3.6. Step 5: time (h) = energy / (chiller W - heat gain W); if chiller W <= heat gain, the target cannot be reached. Published-range comparison lists which source ranges contain the target.

ESTIMATE ONLY.

This tool compares physics limits with the numbers you enter. It does not diagnose a temperature problem, replace a thermometer, or tell you that an axolotl is safe. Published temperature advice differs by source.

What This Calculator Does

Axolotls are cool-water animals, and the veterinary and welfare sources reviewed for this site (LafeberVet, VCA, SPCA NZ and NSW Education) all warn about warm water. This calculator answers three practical questions: (1) can a fan or evaporative cooling reach your target at your room temperature and humidity, (2) how much heat is your tank gaining, and (3) how long would a chiller of a given capacity take to cool the tank.

Can a Fan Cool the Tank Enough?

A fan cools water by evaporation. Evaporation cannot cool water below the wet-bulb temperature of the room air, which depends on air temperature and relative humidity. The calculator uses the Stull (2011) empirical formula at standard sea-level pressure. Stull gives it as valid for 5-99% humidity and -20 to 50 C, except where low humidity and cold temperature occur together; over its valid range errors are -1 to +0.65 C, with a mean absolute error under 0.3 C. The wet-bulb value is a floor, not a prediction: real tanks settle above it because pumps, lights and room heat keep adding warmth. So the result can only say that a target is impossible by evaporation alone, or that it is not ruled out.

Worked values from the Stull (2011) formula
Room temperatureRelative humidityWet-bulb floor for fan cooling
22 C (72 F)50%15.4 C (59.8 F)
26 C (79 F)50%18.9 C (65.9 F)
28 C (82 F)40%18.8 C (65.9 F)
30 C (86 F)60%24.0 C (75.2 F)

At 26 C and 50% humidity the floor is 18.9 C, so a fan cannot bring water to 18 C in that room. At 22 C and 50% it is 15.4 C, so a fan is not ruled out for 18 C. NSW Education's school guidance mentions draping a damp towel over the aquarium with a fan blowing across it during heat waves; the wet-bulb floor still applies to any evaporative method.

How Much Heat Is the Tank Gaining?

Two inputs are available. Equipment watts: most of the electrical power drawn by submerged equipment such as a pump ends up as heat in the water, and 1 W equals 3.412 BTU/h. This is only part of the load because it leaves out heat from the room and from lights. Measured warming is better: turn cooling off, note the temperature rise over a number of hours, and the calculator converts it to watts using the heat capacity of water (4.186 kJ per kg per degree C, taking 1 L of water as 1 kg).

Example: 100 L that warms 1.5 C in 6 hours is gaining about 29 W (99 BTU/h). Measure while the water is close to your target temperature. Water that is warmer than the target gains less heat from the room than it will once chilled, so a test started warm underestimates the load.

How Long Would a Chiller Take?

Energy to cool the water = volume x 4.186 x temperature drop. Cooling 100 L from 24 C to 20 C takes about 465 Wh. With a 150 W chiller and 29 W of heat gain, the net cooling is 121 W, so the time is about 3.8 hours. If the chiller capacity is not larger than the heat gain, it can never reach the target. The calculation ignores the heat stored in glass, decor and substrate, so real cooling takes longer.

Why Not Use a Volume Rule of Thumb?

Some chiller guides use a volume rule. Bulk Reef Supply gives (tank volume in US gallons x 8.3) x temperature drop in F as a BTU/h figure, and hygger uses 8.34 x US gallons x (room temperature - target) plus equipment heat and a 25% buffer. The 8.3 to 8.34 factor is the heat in BTU needed to change one US gallon of water by 1 F, so the volume term is the energy to change the temperature once, not a continuing cooling load. The steady load is the heat the tank keeps gaining from the room and equipment, which is why this calculator asks for watts or a measured warming rate. The volume rules are rules of thumb, not validated standards.

Reading the Result Against Published Temperatures

The calculator lists which published ranges contain your target. OATA gives 10-22 C, NSW Education gives an optimum of 15-18 C and never above 22 C, LafeberVet prefers 15.6-17.8 C, and SPCA NZ gives 17-18 C. VCA and LafeberVet describe illness risk above 24 C. These figures differ, so the tool shows each one instead of a single verdict. See the axolotl water temperature guide for the full comparison and cooling methods, and the axolotl care guide for other requirements.

Limits

  • Wet-bulb is a lower bound, not a forecast.
  • The Stull formula is calibrated for sea-level pressure and is not valid where low humidity and cold temperature occur together.
  • The heat-gain estimate is only as good as your thermometer and the conditions during the test.
  • Stored heat in glass and decor is ignored, so cooling times are underestimates.
  • Fans increase evaporation; top up with conditioned water of similar temperature.
  • If your animal looks unwell, contact an exotic-animal veterinarian.

Calculator References

Companion Ecosystem

Related Aquarium Calculators

3 Companion Tools

Frequently Asked Questions

Why does humidity matter for fan cooling?

Evaporation cools only while the air can take up more water. In humid air the wet-bulb temperature is close to the air temperature, so a fan can cool the water very little. In dry air the floor is much lower.

Does a result of 'not ruled out' mean a fan will work?

No. It only means the target is above the evaporative floor. Heat from pumps, lights and the room keeps the real water temperature above that floor, so check with a thermometer.

How do I measure how fast my tank warms?

Switch off cooling, record the water temperature, and read it again after several hours, ideally starting near your target temperature. Enter the rise and the hours. Do not run this test during a heat wave if the water is already near the upper limits in the sources.

Why is my chiller time longer than the calculator says?

The calculator ignores heat stored in the glass, decor and substrate and assumes the rated capacity applies at your room temperature. Both make the real time longer.

Does the calculator tell me what temperature is safe?

No. Sources differ: OATA gives 10-22 C, NSW says never above 22 C, and LafeberVet and VCA warn of illness above 24 C. The tool shows which published ranges include your target.

Can I use Fahrenheit and BTU/h?

Yes. Temperatures can be entered in C or F, and chiller capacity in watts or BTU/h. Internally the calculation converts to C and W.